Technical Data | |||||
Model | SUN-20K-G02-LV | SUN-25K-G02-LV | SUN-30K-G02-LV | ||
Input Side | |||||
Max. DC Input Power (kW) | 26 | 32.5 | 39 | ||
Max. DC Input Voltage (V) | 800 | ||||
Start-up DC Input Voltage (V) | 250 | ||||
MPPT Operating Range (V) | 200~700 | ||||
Max. DC Input Current (A) | 40+40 | 40+40+40 | 40+40+40+40 | ||
Max. Short Circuit Current (A) | 60+60 | 60+60+60 | 60+60+60+60 | ||
Number of MPPT / Strings per MPPT | 2/3 | 3/3 4/3 | |||
Output Side | |||||
Rated Output Power (kW) | 20 | 25 | 30 | ||
Max. Active Power (kW) | 22 | 27.5 | 33 | ||
Nominal Output Voltage / Range (V) | 3L/N/PE 127/0.85Un-1.1Un,220 /0.85Un-1.1Un (this may vary with grid standards) | ||||
Rated Grid Frequency (Hz) | 60 / 50 (Optional) | ||||
Operating Phase | Three phase | ||||
Rated AC Grid Output Current (A) | 52.5 | 65.6 | 78.7 | ||
Max. AC Output Current (A) | 57.8 | 72.2 | 86.6 | ||
Output Power Factor | 0.8 leading to 0.8 lagging | ||||
Grid Current THD | <3% | ||||
DC Injection Current (mA) | <0.5% | ||||
Grid Frequency Range | 57~62 | ||||
Efficiency | |||||
Max. Efficiency | 98.7% | ||||
Euro Efficiency | 98% | ||||
MPPT Efficiency | >99% | ||||
Protection | |||||
DC Reverse-Polarity Protection | Yes | ||||
AC Short Circuit Protection | Yes | ||||
AC Output Overcurrent Protection | Yes | ||||
Output Overvoltage Protection | Yes | ||||
Insulation Resistance Protection | Yes | ||||
Ground Fault Monitoring | Yes | ||||
Anti-islanding Protection | Yes | ||||
Temperature Protection | Yes | ||||
Integrated DC Switch | Yes | ||||
Remote software upload | Yes | ||||
Remote change of operating parameters | Yes | ||||
Surge protection | DC Type II / AC Type II | ||||
General Data | |||||
Size (mm) | 362W×577H×215D | 647.5W×537H×303.5D | |||
Weight (kg) | 25.5 | 44.5 | |||
Topology | Transformerless | ||||
Internal Consumption | <1W (Night) | ||||
Running Temperature | -25~65ºC, >45ºC derating | ||||
Ingress Protection | IP65 | ||||
Noise Emission (Typical) | <45 dB | ||||
Cooling Concept | Smart cooling | ||||
Max. Operating Altitude Without Derating | 2000m | ||||
Warranty | 5 years | ||||
Grid Connection Standard | CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98, VDE 0126-1-1, RD 1699, C10-11 | ||||
Operating Surroundings Humidity | 0-100% | ||||
Safety EMC / Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | ||||
Features | |||||
DC Connection | MC-4 mateable | ||||
AC Connection | IP65 rated plug | ||||
Display | LCD1602 | ||||
Interface | RS485/RS232/Wifi/LAN |